TTR-I Multi Functional Electrical Test Instrument Power Transformer TTR Tester
Overview Package size per unit product 58.00cm * 45.00cm * 36.00cm Gross weight per unit product 22.000kg TTR-I Multi Fu;
Basic Info
Model NO. | TTR-I |
Functions | Test Turns Ratio and Group Vector of Transformer |
Application Field | Electrical Industry, Transformer Manufacturer |
Features | Multi Functional Power Transformer TTR Tester |
Reference Standards | IEC76-1 and IEC60044 |
Ratio Measurement Range | 1-10000 |
Group Measurement | 1-12 |
Max. Test Timestest Voltage | AC 0~80V Continuously, Frequency 50Hz |
Dimension | 400mm*350mm*200 mm |
Weight | 8kg |
Power Supply | AC 220V, 50Hz/60Hz |
Delivery Lead Time | 7 Days After The Order Is Confirmed |
Shipping Method | Suggest to Ship by Air or Express |
Trade Terms | EXW, Fob, DDU, Cit, etc. |
Payment Term | 30% as Deposit, The Balance Before Delivery |
Transport Package | TTR Tester Packed in Veneer Case |
Specification | 400mm*350mm*200 mm, 7kg |
Trademark | Delta |
Origin | China Mainland |
HS Code | 9031809090 |
Production Capacity | 1000 Sets TTR Tester / Month |
Packaging & Delivery
Package size per unit product 58.00cm * 45.00cm * 36.00cm Gross weight per unit product 22.000kgProduct Description
TTR-I Multi Functional Electrical Test Instrument Power Transformer TTR Tester
Product Description- TTR-I Multi Functional Electrical Test Instrument Power Transformer TTR Tester For Three Phase Transformer Testing is designed according IEC76-1 and IEC60044.
TTR-I Multi Functional Electrical Test Instrument Power Transformer TTR Tester For Three Phase Transformer Testing can be applied to test the turns ratio and group vector of single or three phase transformer.
The connection group of three phase transformer also can be calculated with the ratio.
All parameters can be measured in one test for three phase transformer.
No. | Item Name | TTR-I Multi Functional Electrical Test Instrument Power Transformer TTR Tester |
1 | Ratio measurement range | 1-10000 |
2 | Group measurement | 1-12 |
3 | Phase measurement error | 1 degree |
4 | Ratio measurement error | 1-2000 ± 0.2%RDG 2000-10000 ± 0.5%RDG |
5 | Test voltage | AC 0~80V continuously, frequency 50Hz |
6 | Power supply | AC220V ± 10%, 50Hz/60Hz |
7 | Working environment | 0-50°C, ≤85%RH |
9 | Size | 400mm*350mm*200 mm |
10 | Weight | 7kg |
11 | Length of test cables | 8 meters |
Parameters Testing / Type of Transformer | Single Phase Power Transformer | 3 Phase Power Transformer | CT | PT |
Turns Ratio Testing | Yes | Yes | Yes | Yes |
Phase Angle Testing | Yes | Yes | Yes | Yes |
Polarity Testing | Yes | Yes | Yes | Yes |
Vector Group Testing | / | Yes | No | No |