Transformer Comprehensive Analyze CT and PT Transformer Turns Ratio Tester TTR
Basic Info
Model NO. | TTR-10000 Transformer turn ratio tester |
Control | Computer Control |
Weight | 8 Kgs |
Power Source | AC220V+_10%, 50Hz |
Ratio Testing Range | 1- 10000 |
Group Testing Range | 1-12 |
Input Power | 40va |
Connect | Standard AC Socket 60320 |
Function | Transformer Ratio, Group, Polarity Test |
Input Volts | 185VAC~250VAC |
Allowable Frequency | Transformer Ratio, Group, Polarity Test |
Transport Package | in Standard Exportation Plywood Case |
Specification | 430 * 320 *215mm3 |
Trademark | FUOOTECH |
Origin | Chongqing, China |
HS Code | 9030849000 |
Production Capacity | 1000 PCS/Month |
Product Description
During the processing of the semi-finished products and the finished products in transformer production, the transformer newly installation before using, or according to IEC and national standard, the turns ratio or voltage ratio should be tested in the circle rate. Traditional bridge method is complicated, and can't read the data directly, and you have to make conversion, the testing results are data of one phase.FT-TTR-10000 Turns ratio tester overcomes the shortcomings of traditional bridge method. The monitor adopts big screen with lattice liquid crystal, which has the function of indicating by menu, operating easily and directly. It finishes test of three-phase voltage ratio or turns ratio once, fast testing and high precise.
FT-TTR-10000 Turns ratio tester is applied to measure the voltage ratio of three or single phase transformer. All the data and test results are shown on a digital LCD screen. All the test results could be printed by the micro printer or saved in the storage of the tester. The tester has a good performance on auto protection and anti-disturb.
1. English menu prompt, simple and convenient operation.2. Ratio measurement range is large: 1-100003. Function is powerful: not only can be used for single phase measurement, and can realize three-phase winding automatic test, connected groups can be chosen arbitrarily, a complete measurement of AB, BC, CA three-phase variable ratio, error, line group parameters.
4. Measuring speed. (Finish three-phase simultaneous measuring only requires several seconds )
5. Measuring completed, automatically cut off the power.
6. Sets data, measurement results are automatically saved, can view previous data.
7. Measuring transformer loaded, only an input ratio.
8. Easy to carry, suitable for field operations.
Product ParametersRatio testing range | 1- 10000 |
Group testing range | 1-12 |
Accuracy | 1-1000 0.2%, 1000-10000 0.5% |
Power | AC220V ±10%,50HZ |
Temperature | -5ºC~40ºC |
Relative humidity | <85% |
Volume | 430×320×215mm3 |
Weight | 8Kg |