banner
Products
Quality and performance are the hallmarks of our products.
IEC76-1 Automatic Three Phase Transformer Turns Ratio TTR Tester

IEC76-1 Automatic Three Phase Transformer Turns Ratio TTR Tester

IEC76-1 Automatic Three Phase Transformer Turns Ratio TTR Tester Introduction GDBC-901 is applied to measure the voltage;
Basic Info
Model NO. GDBC-901
Turns Ratio Resolution 0.0001
Test Voltage 0~180V
Printing Print The Test Results by Micro Printer
Relative Humidity ≤85% No Condensation
Power Input 220V±10% 50Hz±1Hz
Working Temperature -20ºC~40ºC
Transport Package Standard Wooden Case
Specification 22KG
Trademark GOLD
Origin Chongqing China(Mainland)
HS Code 9031809090
Production Capacity 500pieces/Month
Product Description

IEC76-1 Automatic Three Phase Transformer Turns Ratio TTR Tester


Introduction

GDBC-901 is applied to measure the voltage ratio of three or single phase transformer. All the data and test results are showed on a 320*240 LCD. All the test results could be printed by the micro printer or saved on the storage of the tester. The tester has a good performance on auto protection and anti-disturb.

Main application

  • GDBC-901 Three Phase Transformer Turns Ratio TTR Tester is designed according IEC76-1 and IEC60044.
  • The voltage ratio measurement for three or singe phase transformer.
  • The group vector measurement for three phase transformer.
  • The polarity measurement for single phase transformer or CT/PT.
  • Voltage ratio error calculation.
  • Current transformer ratio measurement.
  • Excitation current measurement in ratio testing.
  • Reproduction the AC test voltage from power source to reduce the effects of bad power source.
  • Save the test results in the memory internal the tester.
  • Print the test results by micro printer.
  • Reverse connection detect unit to prevent the high voltage injected to operator.
  • Over current protection unit integrated in software and hardware.
  • Upload the test results to PC by RS232 and make word report by software.

Specifications

1Item NameGDBC-901 IEC76-1 Automatic Three Phase Transformer Turns Ratio TTR Tester
2Ratio measurement range0.8-10000
3Group measurement1-12
4Phase measurement error1 degree
5Ratio measurement error1-2000 ± 0.2%RDG 2000-10000 ± 0.5%RDG
6Test voltage0~80V, frequency 50Hz
7Power supplyAC220V ± 10%, 50Hz/60Hz
8Environment temperature0-50°C
9Humidity≤85%R
10Dimension58*45*36CM
11Weight22Kg

IEC76-1 Automatic Three Phase Transformer Turns Ratio TTR Tester

IEC76-1 Automatic Three Phase Transformer Turns Ratio TTR Tester

IEC76-1 Automatic Three Phase Transformer Turns Ratio TTR Tester

IEC76-1 Automatic Three Phase Transformer Turns Ratio TTR Tester

IEC76-1 Automatic Three Phase Transformer Turns Ratio TTR Tester

Send inquiry