Automatic CT PT Analyser Ctpt Characteristic Tester Transformer Polarity Ratio Analyzer
EPCP-III CT/PT Analyzer (Full Functions) General Information: EPCP-III is portable analyzer designed for analyzing curre;
Basic Info
Model NO. | EPCP-III |
Primary Current Output | 0-1000A |
Excitation Accuracy | Less Than 0.5% (0.2%*Reading+0.3%*Range) |
Secondary Winding Resistance Measurement | 0.1-300ohm |
Secondary Real Load Measurement | 5-500va |
Phase Measurement (Angle Difference) | 4min |
Resolution | 0.1min |
CT Ratio Measurement Range | Less Than 25000A/5A(5000A/1A) |
PT Ratio Measurement Range | Less Than 500kv |
Operating Temperature | -10~+40degree |
Relative Humidity | Less 90rh% |
Altitude | Less Than 1000m |
Current Transformer (CT) | Auto Calculation of Knee Point Value |
Polarity | Yes |
Transport Package | Plywood Case with Warter Proof Plastic |
Specification | 410mm*260mm*340(mm) |
Trademark | EP Hipot Electric |
Origin | China |
HS Code | 9030820000 |
Production Capacity | 2000/Year |
Product Description
EPCP-IIICT/PT Analyzer (Full Functions)
General Information:
EPCP-III is portable analyzer designed for analyzing current transformers and voltage transformers of protection or measurement use, which is suitable for laboratory and on-site test.
Features:
- Support detection of CT and PT
- No need to connect other auxiliary equipment, can complete all test items, and complete the excitation and transformation ratio polarity test at the same time in one test.
- Fast printer, which can print test results directly on site.
- Easy to operate, with intelligent prompts, making it easier for users to operate.
- Large screen LCD, graphical display interface.
- Automatically give CT/PT (excitation) inflection point value according to regulations.
- Automatically give 5% and 10% error curves.
- 3000 sets of test data can be saved, which will not be lost after power failure.
- Support U disk transfer data, can be read through a standard PC, and generate WORD report.
- Small and light weight ≤22kg, very conducive to field testing.
1. Function Table
I. Current Transformer (CT) | II. Voltage Transformer (PT) |
1. Excitation Characteristic Test | 1. Excitation Characteristic Test |
2. Auto Calculation of Knee Point Value | 2. Auto Calculation of Knee Point Value |
3. Auto 5% and 10% error curves, can measure ALF | 3. Transformer Ratio Test |
4. Transformer Ratio Test | 3. Polarity |
5. Polarity | 4. Ratio difference measurement |
6. Ratio difference measurement | 5. Phase (angle difference) measurement |
7. Phase (angle difference) measurement | 6. Withstand Test of Power Frequency Alternating Current |
8. Primary Current Injecting | 7. Actual Secondary Load Test |
9. Withstand Test of Power Frequency Alternating Current | 8. Secondary Winding Test |
10. Secondary Load Test | |
11. Secondary Winding Test | |
12. Measuring the volt-ampere characteristics of medium and low voltage CTs and zero sequence CTs | |
13. Measure GIS, casing CT | |
14. Comprehensive test, complete excitation and transformation ratio polarity at the same time in one test |
2. Technical Parameter Table
Operational Power Supply: | AC220V±10%, 50Hz | |
Single Machine Output: | 0~2500Vrms, 5kVA (maximum setting value 20A) | |
Primary Current Output: | 0~1000A | |
Excitation accuracy | ≤0.5% (0.2%*reading+0.3%*range) | |
Secondary winding Resistance measurement | Range | 0.1~300Ω |
Accuracy | ≤0.5% (0.2%*reading+0.3%*range) | |
Secondary real Load measurement | Range | 5~500VA |
Accuracy | ≤0.5% (0.2%*reading+0.3%*range) ±0.1VA | |
Phase measurement (Angle difference) | Accuracy | 4min |
Resolution | 0.1min | |
CT ratio measurement range | Range | ≤25000A/5A(5000A/1A) |
Accuracy | ≤0.5% | |
PT ratio measurement range | Range | ≤500KV |
Accuracy | ≤0.5% | |
Operating Temperature: | -10ºC~+40ºC | |
Relative Humidity: | <90RH% | |
Altitude: | ≤1000m | |
Overall Dimension (Length × Width × Height): | 410mm * 260mm * 340(mm) | |
Weight: | ≤22 kg |